KL- 602 with CE mark Veterinary Syringe Pump

KL- 602 with CE mark Veterinary Syringe Pump
Product Detailed
Related Categories:Physical Therapy Equipments
KL-602 Veterinary Syringe Pump Infusion modes: 1. Flow rate 2. Time-based 3. Body weigh

KL-602 Veterinary Syringe Pump

Features:

1. Applicable syringe: 12 brands for user-defined

2. Occlusion sensitivity: adjustable

3. Can be stacked up and integrated into multi-channel

4. Syringe size: 10, 20, 30, 50 ml

5. Accuracy: ±2%

6. Flow rate: 0.1-1300 ml/h

7. KVO rate: 0.1-1 ml/h in 0.1 ml/h increments, adjustable

Technical Specifications:

Model

KL-602 Veterinary Syringe Pump with CE mark

Syringe Size

10, 20, 30, 50 ml

Applicable Syringe

2 brands built-in (BD, B. Braun), 10 brands for user-defined

Volume

0.1-9999 ml

<1000 ml in 0.1 ml increments

≥1000 mL in 1 ml increments

Flow Rate

Syringe 10 ml: 0.1- 400 ml/h

Syringe 20 ml: 0.1- 600 ml/h

Syringe 30 ml: 0.1-900 ml/h

Syringe 50 ml: 0.1-1300 ml/h

<100 ml/h in 0.1 ml/h increments or decrements

≥100 ml/h in 1 ml/h increments or decrements

Bolus Rate

Syringe 10 ml: 400 ml/h

Syringe 20 ml: 600 ml/h

Syringe 30 ml: 900 ml/h

Syringe 50 ml: 1300 ml/h

Accuracy

±2%

Infusion Mode

Flow rate: ml/min, ml/h

Time-based

Body weight: mg/kg/min, mg/kg/h, ug/kg/min, ug/kg/h

KVO Rate

0.1- 1ml/h in 0.1 ml/h increments or decrements, adjustable

Alarms

Occlusion, syringe drop off, near empty, end program, low pressure, end battery, AC power off, motor malfunction, unattended pump, syringe moved accidently, pressure sensor error

Additional Features

Syringe identification, bolus, real-time shift totals, occlusion pressure release, mute, automatic power switching, residue reminder, system memory

Occlusion Sensitivity

High: 0.02-0.06 Mpa

Medium: 0.06-0.09 Mpa

Low: 0.09-0.12 MPa

Power Supply, AC

110/230 V (optional), 50/60 Hz, 20 VA

Battery

9.6V ±1.6 V, rechargeable

Battery Life

5 hours at 5 ml/h

Working Temperature

5-40°C

Relative Humidity

20-90%

Atmospheric Pressure

860-1060 hpa

Size

314*167*140 mm

Weight

2.5 kgs

Safety Classification

Class II, type CF

We focus on medical pumps:

1. Infusion Pump (Volumetric Pump, IV Pump)

2. Syringe Pump

3. Enteral Feeding Pump

4. Irrigation Pump

5. Infusion Management System

Innovative Infusion Systems, Since 1994

KellyMed

In 1994, the first Chinese-made Infusion Pump was launched by KellyMed.

In 2010, KellyMed enjoyed a No. 1 market share of Infusion Pump in China.

KL- 602 with CE mark Veterinary Syringe Pump



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.